The transfer amplitude frequency characteristic of the series resonant circuit

The transfer amplitude frequency characteristic of the series resonant circuit

Series resonant circuit is a circuit structure that exhibits a special response at a specific frequency. The amplitude-frequency characteristic of this circuit is an important indicator for analyzing the performance of the circuit. This circuit is composed of inductors, capacitors and resistors. When the input signal’s frequency is equal to the inherent resonant frequency of the circuit, the circuit will present a large output. This phenomenon is called resonance.
When analyzing a series resonant circuit, the first step is to understand its basic components. The inductive elements in the circuit store magnetic energy, the capacitive elements store electric energy, and the resistive elements represent the energy loss of the circuit. When an alternating signal passes through the circuit, the inductors and capacitors will produce opposite phase changes. At a specific frequency, these two effects cancel each other out, causing the circuit to exhibit pure resistive characteristics. At this point, the impedance of the circuit reaches its minimum value and the current reaches its maximum value, which is the resonant state.
The amplitude-frequency characteristic of transmission describes the rule of the ratio of the output amplitude of the circuit to the input signal amplitude as the frequency changes. In the low-frequency region, the impedance of the capacitor is relatively large, dominating the circuit behavior; in the high-frequency region, the impedance of the inductor is relatively large, dominating the circuit behavior. Only near the resonant frequency does the transmission amplitude of the circuit show significant changes. This characteristic can be represented by a bell-shaped curve, with the peak of the curve corresponding to the resonant frequency, and gradually decreasing on both sides.
The formula for calculating the resonant frequency is f0 = 1/(2π√LC), where L is the inductance value and C is the capacitance value. This frequency is solely determined by the values of the inductance and capacitance, and is independent of the resistance. However, the size of the resistance affects the shape of the resonance curve, specifically through the quality factor Q value. The Q value is defined as the ratio of the resonant frequency to the bandwidth, reflecting the selectivity of the circuit. A higher Q value results in a sharper resonance curve and better selectivity of the circuit; conversely, a lower Q value leads to a flatter curve and poorer selectivity.
In practical applications, the selectivity characteristic of the series resonant circuit makes it highly suitable for use in frequency selection circuits. For instance, in a radio receiver, the resonant circuit can be utilized to select a specific frequency signal from numerous signals. Additionally, resonant circuits are also commonly employed in filter design. By appropriately selecting component parameters, the desired frequency response characteristics can be achieved. Moreover, in power systems, resonant circuits can be used for reactive power compensation, thereby enhancing the system’s power factor.
The transmission amplitude-frequency characteristic of a series resonant circuit is usually measured using the sweep frequency method. By changing the frequency of the input signal and simultaneously measuring the amplitude of the output signal, a complete frequency response curve can be plotted. Modern testing instruments such as network analyzers can automatically complete this process, significantly improving the measurement efficiency and accuracy. During the measurement process, it is necessary to pay attention to the output impedance of the signal source and the load effect, as these factors may all affect the measurement results.
When designing a series resonant circuit, several engineering factors need to be taken into account. Firstly, the selection of component parameters directly determines the resonant frequency and Q value. Secondly, the actual characteristics of the components, such as the parasitic resistance of the inductor and the equivalent series resistance of the capacitor, etc., these non-ideal factors will affect the circuit performance. Moreover, temperature stability is also an important consideration, especially for applications that require long-term stability.
The theoretical analysis of series resonant circuits is usually based on ideal component models, but in practical applications, various non-ideal factors need to be taken into account. For instance, the resistance of the wire in the inductor will cause additional energy loss, and the dielectric loss of the capacitor will also reduce the Q value. These factors often result in the performance of the actual circuit being lower than the theoretical expectation. Therefore, appropriate margins need to be reserved during design. At the same time, the skin effect and distributed parameter effects in high-frequency applications also require special attention.
With the development of electronic technology, the application fields of series resonant circuits have been continuously expanding. In power electronics, resonant converters utilize the resonant characteristics to achieve high-efficiency energy conversion; in wireless charging systems, resonant coupling improves the energy transmission efficiency; in the sensor field, resonant circuits are used for high-precision measurement. All these applications fully utilize the unique frequency characteristics of resonant circuits.
From an engineering practice perspective, optimizing the performance of a series resonant circuit requires comprehensive consideration of various factors. On one hand, the Q value needs to be increased to achieve better selectivity; on the other hand, sufficient bandwidth must be ensured to meet the requirements of signal transmission. This necessitates careful design in aspects such as component selection, circuit layout, and process implementation. Modern computer-aided design tools can significantly simplify this process, enabling rapid identification of the optimal design solution through simulation analysis.
The analysis of the frequency characteristics of series resonant circuits not only has theoretical significance but also holds significant practical value. By deeply understanding the essence of resonance phenomena, engineers can design more superior circuit systems. Moreover, with the development of new materials and new technologies, the performance of resonant circuits will continue to improve, providing new possibilities for the development of electronic technology.
In the future, series resonant circuits will remain an important research topic in the field of electronic engineering. With the rise of emerging technologies such as 5G communication and the Internet of Things, the demand for high-frequency and high-selectivity circuits will continue to increase. This requires engineers to constantly explore new circuit topologies and implementation methods to meet increasingly stringent performance requirements. At the same time, the combination of resonant circuits with other technologies will also create more innovative applications.


Post time: Dec-29-2025

Send your message to us:

Write your message here and send it to us